Dosimetric Study of Custom-made Pelvic Perspex Phantom using Single-Energy Mode (SECT) and Dual-Energy Mode (DECT) Computed Tomography

Main Article Content

Siti Hajar Zuber
Nursyatina Abdul Raof
Rafidah Zainon
Abd Aziz Tajuddin

Abstract

Introduction: A custom-made Perspex male pelvic phantom was developed to measure and to compare absorbed, surface and effective doses obtained from Single-Energy and Dual-Energy Computed Tomography (SECT & DECT). Methods: A customised Perspex pelvic phantom that mimicked male Asian reference size was scanned with SECT mode at 80 kV, 100 kV, 120 kV and 140 kV. In addition, the fabricated phantom was also scanned with DECT mode at 80/140 kV. Thermoluminescence dosimeters (TLD) were used to measure the charges and doses obtained from the TLD calibration curve. The absorbed dose, surface dose and effective dose obtained from SECT and DECT were measured and compared between these two modes. Results: The DECT showed 55.9 % dose reduction compared to SECT at 140 kV tube voltage. It shows that DECT can be used with radiation dose sparing, and it is in good agreement with routine CTDI phantom study. The effective dose of DECT of the abdominal imaging was within the acceptable effective dose limit of AAPM Report No. 96. This study also found that the surface dose was lower than values re- ported in previous studies for both modes. Conclusion: The fabricated Perspex phantom shows a great potential to be considered as an alternative phantom for the commercially existing phantom in CT dosimetry application.

Downloads

Download data is not yet available.

Article Details

How to Cite
Zuber, S. H., Abdul Raof, N., Zainon, R., & Tajuddin, A. A. (2021). Dosimetric Study of Custom-made Pelvic Perspex Phantom using Single-Energy Mode (SECT) and Dual-Energy Mode (DECT) Computed Tomography. Malaysian Journal of Medicine and Health Sciences, 17(2), 72–77. Retrieved from http://mjmhsojs.upm.edu.my/index.php/mjmhs/article/view/295
Section
Original Articles

References

Smyth JM, Sutton DG, Houston JG. Evaluation of the quality of CT-like images obtained using a commercial flat panel detector system. Biomed Imaging Interv J. 2006;2(4).

MA Hurrell, APH Butler, NJ Cook, PH Butler, JP Ronaldson, R Zainon. Spectral Hounsfield units: a new radiological concept. European Radiology. 2012. 22 (5), 1008-1013.

Brown CL, Hartman RP, Dzyubak OP, Takahashi N, Kawashima A, McCollough CH, et al. Dual-energy CT iodine overlay technique for characterization of renal masses as cyst or solid: a phantom feasibility study. Eur Radiol. 2009;19(5):1289.

Bauhs JA, Vrieze TJ, Primak AN, Bruesewitz MR, McCollough CH. CT dosimetry: comparison of measurement techniques and devices. Radiographics. 2008;28(1):245–53.

McCollough CH, Leng S, Yu L, Cody DD, Boone JM, McNitt-Gray MF. CT dose index and patient dose: they are not the same thing. Radiology. 2011;259(2):311–6.

Takegami K, Hayashi H, Yamada K, Mihara Y, Kimoto N, Kanazawa Y, et al. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors. Radiol Phys Technol. 2017;10(1):49–59.

Khan F, Stathakis S. The Physics of Radiation Therapy. Med Phys. 2010 Mar 1;37:1374–5.

Ade N, van Eeden D, du plessis F. Characterization of Nylon-12 as a water-equivalent solid phantom material for dosimetric measurements in therapeutic photon and electron beams. Appl Radiat Isot. 2019 Oct 1;155:108919.

Yusof MFM, Hamid PNKA, Tajuddin AA, Abdullah R, Hashim R, Bauk S, et al. Characterization and attenuation study on tannin-added Rhizophora spp. particleboard at high energy photon and electron. In: AIP Conference Proceedings. AIP Publishing; 2017. p. 40002.

Marashdeh MWM. Fabrication, Characterization and Dosimetric Evaluation of Rhizophora Spp. Binderless Particleboard Phantom for the Mammography and Diagnostic X-rays. Universiti Sains Malaysia; 2013.

Zuber SH, Hashikin NAA, Mohd Yusof MF, Hashim R. Physical and Mechanical Properties of Soy- lignin Bonded Rhizophora spp. Particleboard as a Tissue-equivalent Phantom Material. Bioresour Vol 15, No 3 [Internet]. 2020; Available from: https://ojs.cnr.ncsu.edu/index.php/BioRes/article/view/BioRes_15_3_5558_Zuber_Soy_Lignin_Bonded

Sharifian S, Shahbazi GD. Dose Assessment in multidetector computed tomography (CT) of polymethylmethacrylate (PMMA) phantom using American Association of Physicists in Medicine- Task Group Report No. 111 (AAPM-TG111). 2017;

Ruan C, Yukihara EG, Clouse WJ, Gasparian PBR, Ahmad S. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology. Med Phys. 2010;37(7Part1):3560–8.

Abuhaimed A, Martin CJ, Sankaralingam M, Gentle DJ, McJury M. An assessment of the efficiency of methods for measurement of the computed tomography dose index (CTDI) for cone beam (CBCT) dosimetry by Monte Carlo simulation. Phys Med Biol. 2014;59(21):6307.

White DR, Buckland-Wright JC, Griffith R V, Rothenberg LN, Showwalter CK, Williams G, et al. Report 48. J Int Comm Radiat Units Meas. 1992;(1):NP-NP.

Radaideh KM. A custom made phantom for dosimetric audit and quality assurance of three-dimensional conformal radiotherapy. J Sains Nukl Malaysia. 2017;24(1):48–58.

Sim GS, Wong JHD, Ng KH. The use of radiochromic EBT2 film for the quality assurance and dosimetric verification of 3D conformal radiotherapy using Microtek ScanMaker 9800XL flatbed scanner. J Appl Clin Med Phys. 2013;14(4):85–95.

Sina S, Karimipoorfard M, Lotfalizadeh F, Sadeghi M, Zamani E, Zehtabian M, et al. Comparison of the response of TLD-100, and TLD-100H dosimeters in diagnostic radiology. 2014.

Adams EJ, Brettle DS, Jones AP, Hounsell AR, Mott DJ. Estimation of fetal and effective dose for CT examinations. Br J Radiol. 1997;70(831):272–8.

Kalra MK, Maher MM, Toth TL, Schmidt B, Westerman BL, Morgan HT, et al. Techniques and applications of automatic tube current modulation for CT. Radiology. 2004;233(3):649–57.

Wrixon AD. New ICRP recommendations. J Radiol Prot. 2008 Jun;28(2):161–8.

Paul J, Banckwitz R, Krauss B, Vogl TJ, Maentele W, Bauer RW. Estimation and comparison of effective dose (E) in standard chest CT by organ dose measurements and dose-length-product methods and assessment of the influence of CT tube potential (energy dependency) on effective dose in a dual-source CT. Eur J Radiol. 2012;81(4):e507– 12.

De Cecco CN, Darnell A, Macías N, Ayuso JR, Rodríguez S, Rimola J, et al. Second-generation dual-energy computed tomography of the abdomen: radiation dose comparison with 64-and 128-row single-energy acquisition. J Comput Assist Tomogr. 2013;37(4):543–6.

Purysko AS, Primak AN, Baker ME, Obuchowski NA, Remer EM, John B, et al. Comparison of radiation dose and image quality from single-energy and dual-energy CT examinations in the same patients screened for hepatocellular carcinoma. Clin Radiol. 2014;69(12):e538–44.

Subhas N, Freire M, Primak AN, Polster JM, Recht MP, Davros WJ, et al. CT arthrography: in vitro evaluation of single and dual energy for optimization of technique. Skeletal Radiol. 2010 Oct;39(10):1025–31.

Wichmann JL, Hardie AD, Schoepf UJ, Felmly LM, Perry JD, Varga-Szemes A, et al. Single-and dual- energy CT of the abdomen: comparison of radiation dose and image quality of 2nd and 3rd generation dual-source CT. Eur Radiol. 2017;27(2):642–50.

McCollough CH, Christner JA, Kofler JM. How effective is effective dose as a predictor of radiation risk? Am J Roentgenol. 2010;194(4):890–6.